Login
SCS Photo Gallery SCS Photos Rooms and Equipment Server Room
View Slideshow

Rooms and Equipment

1. Special... 2. Graduate Lab 3. Undegraduat... 4. The Great... 5. Server Room 6. DSCN1533 7. DSCN1514.JPG 8. DSCN1469.jpg ... 31. IMG_0012.JPG

Server Room

Date: 07/16/2007
Owner: John Flynn
Size: 43 items
nextlast
DSCN1479.jpg
Date: 01/28/2009
Views: 31
DSCN1478.jpg
Date: 01/28/2009
Views: 35
DSCN1477.jpg

Dual PDUs, one going to each UPS, and each UPS is on a seperate circuit. This is good for redundancy.

Date: 01/28/2009
Views: 36
DSCN1475.jpg

The back of the BladeCenter rack. That fiber connection is temporary until we obtain the correct cables.

Date: 01/23/2009
Views: 34
DSCN1474.jpg

IBM BladeCenter H in ECS 202. Note two APC 5000VA UPSes. They are vastly oversized for this configuration, so we will be using them for additional equipment that requires good power redundancy.

Date: 01/23/2009
Views: 31
DSCN1473.jpg

This is the first time we use real PDUs. Power wiring is a lot neater and more convenient.

Date: 01/23/2009
Views: 33
DSCN1472.jpg

One of the newer racks in ECS210.

Date: 01/23/2009
Views: 45
tally-deployment.jpg

Servers in Tallahassee. Top to bottom: tally, sable, meerkat

Date: 12/17/2008
Views: 57
IMG_3271.jpg

The new tape changer holds the tapes in a space-efficient manner compared to the older one.

Date: 07/24/2008
Views: 58
IMG_3269.jpg

Fibrechannel Arbritrated Loop, 4Gbps baby! Note the other tape changer isn't yet connected, and is still on the old server.

Date: 07/24/2008
Views: 60
IMG_3264.jpg

The back of the setup.

Date: 07/24/2008
Views: 46
IMG_3263.jpg

Our new LTO4 backup system. Dell PowerVault TL4000 on the top (really a rebadged IBM System Storage TS3200), the new Dell backup server, and the older IBM LTO3 changer that's still plugged into the previous backup server (not visible).

Date: 07/24/2008
Views: 52
IMG_3262.jpg

I've been unpacking and labeling tapes!

Date: 07/24/2008
Views: 45
IMG_2899.jpg

Cisco 3750 switch + lots of cabling. Whee...

Date: 07/10/2008
Views: 65
IMG_2898.jpg

Stuff that's been unpacked and waiting to be unpacked

Date: 07/10/2008
Views: 47
IMG_2897.jpg

I'm going to put an admin workstation here once the rack gets installed.

Date: 07/10/2008
Views: 48
IMG_2896.jpg

The Dell 2950 and an APC 2200VA UPS.

Date: 07/10/2008
Views: 51
IMG_2895.jpg

Inside the 2950

Date: 07/10/2008
Views: 55
IMG_2891.jpg

2950 slid out on its drawer, opened.

Date: 07/10/2008
Views: 47
IMG_2528_001.jpg

Inside of the R900. CPUs on the right, RAM top and bottom, expansion slots in the middle. And lots of fans.

Date: 06/10/2008
Views: 62
IMG_2525.jpg

Inside the Dell R900

Date: 06/10/2008
Views: 53
IMG_2524.jpg

Back of the server rack

Date: 06/10/2008
Views: 53
IMG_2523.jpg

The server rack after adding the R900.

Date: 06/10/2008
Views: 58
DSCN1298.JPG

Comm rack in ECS 284.

Date: 04/11/2008
Views: 92
DSCN1292.JPG

Our new rack in ECS204. mail, web, and file servers.

Date: 04/07/2008
Views: 86
IMG_0375.JPG

"Bear", Sun x4500, 24TB storage

Date: 04/12/2007
Views: 98
IMG_0373.JPG

One of the disks in "Bear"

Date: 04/12/2007
Views: 101
IMG_0372.JPG

Lots and lots of SATA goodness.

Date: 04/12/2007
Views: 118
IMG_0371.JPG

Mmmm, storage.

Date: 04/12/2007
Views: 202
IMG_0370.JPG

Redundant PSUs. If one fails, the remaining one draws 7 amps!

Date: 04/12/2007
Views: 99
nextlast
Page: 1 2